Pureflo

GAC cartridges

Website comparison sheet · Revision 23 October 2026 · Source: CSD-supplied Pureflo customer catalogue. This is not a certified engineering drawing. Availability and application suitability require confirmation.

View product page

GAC specifications

Catalogue specifications for shortlisting. Confirm the exact configuration, current availability and operating limits with your quotation.

On a small screen, swipe the table sideways to compare columns.

Granular activated carbon — GAC
SpecificationCatalogue value
Ordering exampleGAC1-20 — GAC, 1 micron, 20 inch
Pre- and post-filter rating1 µm
Ordering lengths9.875, 10, 19.875, 20, 30, 40 inches
One-piece lengths described9.875, 19.875, 29.875, 39.875 inches — confirm exact fitted length
MediaWater-washed activated coconut shell carbon
Core / post-filterPolypropylene / wound polypropylene
End type / capsDouble open end (DOE) / black PVC
Inner / outer diameter27.8 mm / 63 mm (2.5 inch)
Maximum temperature82°C
Design flow per cartridge6.8 litres per minute
Maximum pressureNot established by the catalogue pressure-drop statement; request confirmation

Cartridge life depends on contaminant loading, flow, temperature and pH. Confirm the required removal duty and service life with the team.

Related CP cartridge

On a small screen, swipe the table sideways to compare columns.

Granular activated carbon CP
SpecificationCatalogue value
Ordering exampleCP1-20 — CP, 1 micron, 20 inch
Micron options1 and 5 µm in the ordering table
Length options9.875, 10, 19.875, 20, 29.875, 30, 39.875, 40 inches
Media / core / post-filterWater-washed activated coconut shell carbon / polypropylene / wound polypropylene
End typeDouble open end (DOE)
Inner / outer diameter27.8 mm / 63 mm (2.5 inch)
Maximum temperature82°C
Maximum pressureNot established by the catalogue pressure-drop statement; request confirmation
CapacityRequest a confirmed duty rating for your application

The catalogue separately quotes a 2,500 litre chlorine-removal test and 1,400 litres filtration capacity. These are not interchangeable service-life guarantees. Confirm water quality, flow and the applicable duty with the technical team.

Source: Pureflo customer catalogue, printed pages 11–13, 17. Maximum temperature and pressure are separate catalogue ratings; confirm combined operating conditions and liquid compatibility before selection.

Sales: mycsd@nordintech.com · +603 3149 4100 · pureflo.com.my